Vapor Compression Refrigeration Cycle Schematic

The vapor compression uses a circulating liquid refrigerant as the medium usually r134a which absorbs and removes heat from the space to be cooled and subsequently rejects that heat elsewhere the figure depicts a typical single stage vapor compression system the typical vapor compression system consist of four components.
Vapor compression refrigeration cycle schematic. Vapour compression refrigeration cycle p h diagram explain the vapor compression cycle on the t s and p h diagrams for the heated steam at the end of the compression the p h and t s vapor compression cycle for a simple steam compression cooling cycle is shown in the pattern for the steam entering the compressor is in a dry state of saturating dry. T s diagram for actual vapor compression cycle. Vapor compression refrigeration cycle t s diagram below is a possible cyclepad design of a refrigeration cycle. In this cycle the refrigerant is sealed condition in an airtight mechanism is compressed in a compressor which permits the transfer of heat energy.
Vapour compression cycle generally known as vcc is a refrigeration cycle. Vapor compression cycle thermodynamic cycle of heat pumps. The theoretical vapour compression cycle. 36 25 on t s diagram.
An actual vapour compression cycle is shown in fig. A compressor condenser expansion valve and evaporator. A few of the important points of deviations of this cycle as compared to the ideal. Actual vapour compression refrigeration cycle.
The vapor compression refrigeration cycle. The refrigerant absorbs heat from one place and releases it to another place. The diagram at the left shows the components of a vapor compression refrigeration cycle. Actual vapor compression refrigeration cycle fig.
H 3 h 4. 1 in practice the refrigerant enters the compressor at state 1 slightly superheated vapor instead of. The vapor compression refrigeration cycle is nearly 200 years old but it does not seem ready to leave the scene any time soon. And q l h 1 h 4.
Vapor compression cycle working diagram a refrigeration system can also be used as a heat pump in which the useful output is the high temperature heat rejected at the condenser. Q h h 2 h 3. The layout shown below is a clickable image. Most of the differences between the ideal and the actual cycles are because of the irreversibilities in various components which are.
The cop of the refrigerator is given by in the ideal. The cycle as applied in practice however differs considerably from the theoretical cycle. Application of the first law of thermodynamics to the control volume compressor condenser throttle and evaporator gives w s compressor h 2 h 1. Alternatively a refrigeration system can be used for providing cooling in summer and heating in winter.